{"product_id":"icm-controls-icm1501-intermittent-ignition-oil-primary-controls-15-second-eb-168310712099","title":"ICM Controls ICM1501 Intermittent Ignition Oil Primary Controls 15-Second","description":"\u003ch1\u003eICM Controls ICM1501 Intermittent Ignition Oil Primary Controls 15-Second\u003c\/h1\u003e\n\u003chr\u003e\n\u003cimg src=\"https:\/\/images.zentail.com\/9\/e241e42d5eb369ede700a23f15600d47aff67bf468fc7bfecb04c98d1977f986.png\" style=\"float:left; padding:10px; max-width: 500px; max-height: 700px;\"\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003ch2\u003eICM Controls Part Number ICM1501\u003c\/h2\u003e\n\u003cbr\u003e\n\u003ch2\u003eIntermittent Ignition Oil Primary Controls\u003c\/h2\u003e\n\u003cbr\u003e\n\u003ch2\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cbr\u003e\n\u003cli\u003e15 second lockout times\u003c\/li\u003e\n\u003cbr\u003e\n\u003cli\u003eControls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat\u003c\/li\u003e\n\u003cbr\u003e\n\u003cli\u003eSolid state flame sensing circuit\u003c\/li\u003e\n\u003cbr\u003e\n\u003cli\u003eLED on terminal strip indicates system lockout\u003c\/li\u003e\n\u003cbr\u003e\n\u003cli\u003eEnclosed safety switch with external reset button\u003c\/li\u003e\n\u003cbr\u003e\n\u003cli\u003eMounts on standard 4 x 4 in. junction box; select models may be mounted directly on burner housing\u003c\/li\u003e\n\u003cbr\u003e\n\u003cli\u003eC554A Cadmium sulfide flame detector and 24 VAC thermostat required\u003c\/li\u003e\n\u003cbr\u003e\n\u003cli\u003eForm, fit and functional replacement for popular competitive models\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cbr\u003e\n\u003cli\u003eIgnition Type: Intermittent\u003c\/li\u003e\n\u003cbr\u003e\n\u003cli\u003eTiming, safety switch: 15 seconds\u003c\/li\u003e\n\u003cbr\u003e\n\u003cli\u003eMounting bracket: For mounting on a standard 4\" x 4\" junction box or direct mounting on burner housing\u003c\/li\u003e\n\u003cbr\u003e\n\u003cli\u003eElec. rating, contacts (full-load): 7.4 A @ 120 VAC\u003c\/li\u003e\n\u003cbr\u003e\n\u003cli\u003eElec, rating, contacts (locked rotor): 44.4 A @ 120 VAC\u003c\/li\u003e\n\u003cbr\u003e\n\u003cli\u003eTemperature range: -30F to +130F (-34C to +55C)\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003ch2\u003e\u003cstrong\u003eReplaces:\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cbr\u003e\n\u003cul\u003e\n\u003cbr\u003e\n\u003cli\u003eHoneywell: R8184G4066, R8184G1161, R8184G1294\u003c\/li\u003e\n\u003cbr\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cp\u003eICM's Intermittent Ignition Oil Primary Control is ideal for residential oil-fired burners used in boilers, forced air furnaces, water heaters and other oil burning appliances where pre\/post purge is not a safety requirement. It uses a C554A Cadmium Sulfide (cad cell) Flame Detector to monitor the burner flame. In the event of flame failure or flame loss, the control will shut the system down.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003eIn the event of a lockout, pressing and holding in the red external reset button for three seconds will manually reset the safety switch. (For added safety, the button press is activated upon release to ensure that the button can not be permanently held in). \u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003eA status indicator LED on the control board indicates the function of the control and can be used to aid in testing and\/or troubleshooting the control. To initiate a manual lockout of the system, press and hold the reset button when the status LED is off. There is a slight delay before the heat call is implemented. This is to verify the call is valid.\u003c\/p\u003e\n\u003cdiv style=\"clear:both;\"\u003e\u003c\/div\u003e\n\u003cbr\u003e\n\u003ch2\u003eProduct Details\u003c\/h2\u003e\n\u003ctable class=\"product-details\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eICM Controls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eICM Controls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMpn\u003c\/th\u003e\n\u003ctd\u003eICM1501\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"bullet-wrapper\"\u003e\u003cul\u003e\n\u003cli\u003eICM Controls Part Number ICM1501\u003c\/li\u003e\n\u003cli\u003eIntermittent Ignition Oil Primary Controls\u003c\/li\u003e\n\u003cli\u003e15 second lockout times\u003c\/li\u003e\n\u003cli\u003eControls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003cdiv style=\"clear:both;\"\u003e\u003c\/div\u003e\n\u003cbr\u003e\u003ca href=\"\/\/str\/hvacappliancepartssupplies\"\u003eCheck out my other items.\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\n-\t\t\t\u003cdiv class=\"zentail\"\u003ePowered by \u003cimg src=\"https:\/\/app.zentail.com\/assets\/images\/zentail-logo.png\"\u003e\n\u003c\/div\u003e","brand":"Foxcom Supply","offers":[{"title":"Default Title","offer_id":48960925565153,"sku":"eb-168310712099","price":124.17,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0847\/1108\/0161\/files\/s-l1600_77c9ca93-28d9-4909-b2b2-774ab67f8c7f.jpg?v=1787316334","url":"https:\/\/foxcomsupply.shop\/products\/icm-controls-icm1501-intermittent-ignition-oil-primary-controls-15-second-eb-168310712099","provider":"Foxcom Supply","version":"1.0","type":"link"}